A

How to Measure the Aorta Using MRI: A Practical Guide

Journal of Magnetic Resonance Imaging, vol. 52, pp. 971–977

Abstract

A ORTIC DIMENSIONS ARE IMPORTANT in the risk assessment of aortic pathology, aneurysms, dissection, and rupture.However, there is much debate on how, when, and where to measure the aorta.The main imaging techniques used to measure the aorta are transthoracic echocardiography (TTE), computed tomography (CT), and magnetic resonance imaging (MRI).MRI has the advantage over TTE and CT in that it is able to accurately visualize the entire aorta without using ionizing radiation and is able to give additional information on ventricular, valvular and vascular function and flow dynamics.Proximal aortic diameter measurements can vary up to 5 mm between imaging modalities, which can lead to relevant differences in clinical decisions about preventive surgery. 1 The American and European guidelines give recommendations on how to measure the aorta, but these recommendations differ and can be ambiguous.2,3 There are limited MRI guidelines on how to measure the aorta.1,4 Accordingly, still large variations exist in image acquisition and analysis in MRI. 5 The question is: how, when, and where do the guidelines advise us to measure the aorta?We will discuss aortic analysis in MRI and compare these to accepted practice in CT and TTE.This article provides recommendations for clinicians on aortic measurements in the adult population using MRI, with an emphasis on the thoracic aorta. How, When, and Where to MeasureHow: With or Without Aortic Vessel Wall?The normal ascending aortic vessel wall is ~2 mm thick, so inclusion of the wall can account for a 4-mm difference in aortic size.6 Echocardiography guidelines recommend the leading edgeto-leading edge (L-L) method (Fig. 1a) for measuring aortic diameters; consequently, the L-L method has been used in many trials that defined normal aortic size limits.1 Studies comparing multimodality imaging techniques have shown that the inner edge-to-inner edge (I-I) method (Fig. 1b-d) for MRI is in best agreement with the L-L method of echocardiography. 1 Given the high conformity with echocardiographic measurements and that with bright-blood MR angiography (MRA) techniques, only the equivalent of I-I measurements are obtained, and it View this article online at wileyonlinelibrary.com.

Authors 14

  1. Leiden University Medical Center

    Affiliation as printed

    Department of Cardiology Leiden University Medical Center Leiden The Netherlands

    Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands

  2. Leiden University Medical Center

    Affiliation as printed

    Department of Cardiology Leiden University Medical Center Leiden The Netherlands

    Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands

  3. Leiden University Medical Center

    Affiliation as printed

    Department of Radiology Leiden University Medical Center Leiden The Netherlands

    Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

  4. Leiden University Medical Center

    Affiliation as printed

    Department of Radiology Leiden University Medical Center Leiden The Netherlands

    Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

  5. National University of Singapore · SingHealth Duke-NUS Academic Medical Centre · Duke-NUS Medical School · National Heart Centre Singapore

    Affiliation as printed

    Cardiovascular Sciences Academic Clinical Programme, Duke‐NUS Medical School Singapore Singapore

    National Heart Centre Singapore National Heart Research Institute Singapore Singapore Singapore

    Cardiovascular Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore

    National Heart Centre Singapore, National Heart Research Institute Singapore, Singapore, Singapore

  6. Eighth Affiliated Hospital of Sun Yat-sen University

    Affiliation as printed

    Department of Radiology Eighth Affiliated Hospital of Sun Yat‐sen University Shenzhen China

    Department of Radiology, Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, China

  7. Maastricht University Medical Centre

    Affiliation as printed

    Department of Cardiology Maastricht University Medical Centre Maastricht The Netherlands

    Department of Cardiology, Maastricht University Medical Centre, Maastricht, The Netherlands

  8. University of California, San Francisco

    Affiliation as printed

    Department of Radiology University of California San Francisco California USA

    Department of Radiology, University of California, San Francisco, California, USA

  9. University Hospital of Basel

    Affiliation as printed

    Department of Radiology Universitätsspital Basel Basel Switzerland

  10. University of Virginia

    Affiliation as printed

    Cardiovascular Division, Department of Medicine University of Virginia Charlottesville Virginia USA

    Cardiovascular Division, Department of Medicine, University of Virginia, Charlottesville, Virginia, USA

  11. Charité - Universitätsmedizin Berlin

    Affiliation as printed

    Department of Radiology Charité – Universitätsmedizin Berlin Berlin Germany

  12. University of California, San Francisco

    Affiliation as printed

    Department of Radiology University of California San Francisco California USA

    Department of Radiology, University of California, San Francisco, California, USA

  13. University of Wisconsin–Madison

    Affiliation as printed

    Department of Radiology University of Wisconsin Madison Wisconsin USA

    Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA

  14. Leiden University Medical Center

    Affiliation as printed

    Department of Radiology Leiden University Medical Center Leiden The Netherlands

    Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands

Cited by 35 stored of 35

No patents citing this paper on Lens.org (checked 2026-10-11).

References 11

11 results